Description
Monsoon Universal pumps do not require a gravity flow of water to start.
Application
- Boost hot and cold water services to the complete home, bathroom, kitchen or cloakroom.
- Pressurise the supply in applications such as loft conversions, where outlets are higher than the water source.
Technical Details
Technical Specification
General |
Product code |
46412 |
Guarantee |
5 years |
WRAS approval |
1404701 |
Features |
Pump type |
Peripheral |
Mechanical seal |
EPDM / PTFE / Al. Oxide |
Anti vibration feet |
|
Inlet strainer(s) |
|
Flexible hoses |
4 |
Run on timer |
3 sec |
Dry run protection |
|
Materials |
Pump body |
Brass |
Impeller |
Brass |
Performance |
Maximum head (closed valve) |
4.5 bar |
Performance @ 9 l/min |
3.8 bar |
Performance @ 18 l/min |
3.2 bar |
Maximum flow |
51 l/min |
Maximum static inlet pressure |
12 metres |
Maximum static outlet pressure |
12 metres |
Maximum working pressure* |
600 kPa (6 bar) |
Maximum ambient air temperature |
40 °C |
Min / Max water temperature** |
Min 4 °C / Max 65 °C |
Flow switch sensitivity (approx) |
0.6 l/min |
Pressure vessel air pre-charge |
1.3 bar (18.5 psi) |
Connections |
Pump connections |
G ¾ male |
Flexible hoses |
Connections (UK model) |
G ¾ female x 22 mm push-in
300 mm long
Isolating valves on all hoses |
Connections (ROI model) |
G ¾ female x 21 mm push-in
300 mm long
Isolating valves on all hoses |
Connections (Export model) |
G ¾ female x G ¾ female
300 mm long |
Motor |
Type |
Induction, auto-reset thermal trip |
Duty rating |
Continuous (S1) @ 9 l/min and above*** |
Electrical |
Power supply/phase/frequency |
230 V a.c./ 1 / 50 Hz |
Current (full load) |
5.1 Amps |
Power consumption |
1135 Watts |
Fuse rating |
13 Amps |
Power cable (pre-wired) |
1.5 metres |
Physical |
Enclosure protection |
IPX4 |
Length |
310 mm |
Width |
162 mm |
Height (excluding hoses) |
243 mm |
Weight (including fittings) |
11.6 Kg |
* The maximum pressure that can be applied to the pump under any installation conditions.