Stuart Turner Monsoon Extra Universal 1.4 bar Single – Water boosting pump

Part Ref: 46349


Monsoon Extra Universal 1.4 bar Single is a quality brass centrifugal single-stage booster pump, designed for larger installations that require higher flow rates.

Category:
Manufacturer:

Asset 1      

Description

It’s high performance makes it an ideal choice for high demand, multiple outlet applications including larger houses, small hotels and leisure facilities where multiple showers would be a requirement.

Application

  • Designed to provide a pressurised water supply from a break tank in either a positive or negative head application.
  • Suitable for commercial or domestic use, pumping hot or cold water.


Technical Details

Technical Specification

General
Product code 46349
Guarantee 3 years
WRAS approval Approved material
Features
Pump type Centrifugal
Mechanical seal EPDM / PTFE / Al. Oxide
Anti vibration feet
Inlet strainer(s)
Flexible hoses 2
Run on timer 3 sec
Dry run protection
Materials
Pump body Brass
Impeller Plastic
Performance
Maximum head (closed valve) 1.4 bar
Performance @ 45 l/min 1.2 bar
Performance @ 90 l/min 0.7 bar
Maximum flow 120 l/min
Minimum Static inlet pressure 1 metre
Maximum static inlet pressure 6 metres
Maximum static outlet pressure 6 metres
Maximum working pressure* 600 kPa (6 bar)
Maximum ambient air temperature 40 °C
Min / Max water temperature** Min 4 °C / Max 65 °C
Flow switch sensitivity 1.0 l/min
Pressure vessel air pre-charge 0.9 bar (13 psi)
Cut in flow 1 l/min (approx)
Cut in pressure 80 kPa (0.8 bar)
Connections
Pump connections G 1 male
Flexible hoses
Connections G 1 male x G 1 female x 300 mm long
Motor
Type Induction type, thermally protected
Duty rating Continuous (S1)
Electrical
Power supply/phase/frequency 230 V a.c./ 1 / 50 Hz
Current (full load) 1.8 Amps
Power consumption 415 Watts
Fuse rating 5 Amps
Power cable (pre-wired) 1.5 metres
Physical
Enclosure protection IPX4
Length 273 mm
Width 159 mm
Height (excluding hoses) 338 mm
Weight (including fittings) 8.7 Kg

* The maximum pressure that can be applied to the pump under any installation conditions.

** A stored water temperature of 60 °C is considered sufficient to meet all normal requirements and will minimise deposition of scale in hard water areas.